Subscribe to our weekly newsletters
Subscribe to newsletter

 

Editor's Note:  Bilco UK provide:-

Fire Protection Fire Detection Protection EvacuationFire Protection Fire Detection Protection Evacuation

Request Information

Home
Include Article
Advertise
 

 

 
 

Links
Request Information
Terms of use
Contact

 

home

   
 

Bilco smoke vents installed at prestige Chelsea development

Leading access doors and vents manufacturer Bilco has completed delivery of automatic smoke vents for prestige high-rise housing on the banks of the River Thames.

Berkeley Homes’ Chelsea Bridge Wharf development offers upmarket living and spectacular views of Battersea Park.

Bilco has supplied 12 REM Automatic Smoke Vents for Phase Four of the development. Seven of these are single leaf vents each equipped with two 24V DC linear actuators that ensure positive, controlled operation. The other five are double leaf smoke vents that utilize four actuators and were specially made to meet the client’s specific size requirement.

The aluminum REM smoke vents are proven to meet BS7346 (part 1) and BS5588 (part 5) and aid firefighters in bringing a blaze under control by removing smoke, heat and gases from a burning building.

Three Bilco Bil-Guard hatch rail systems were also supplied. These provide a permanent means of fall protection for hatch openings as well as aiding access on and off the roof and are easily installed. Bilco worked closely with contractors Bovis Lend Lease and sub-contractors Lakesmere Ltd to ensure the developer received products suited to its needs.

Simon Shand-Brown, Bilco’s sales and marketing manager, said: “95 per cent of all fire related deaths result from smoke inhalation so it is vitally important for new buildings to have installed modern, reliable smoke vents. Bilco Smoke Vents were wired directly into the building management’s fire alarm system and are activated by smoke detectors that are installed throughout the building.”

A major advantage of the REM Automatic Smoke Vent is that if the system is triggered it can be reset remotely simply by flicking a switch. There is no need to physically climb on to the roof and close the vent manually.

Bilco smoke vents also act as a convenient way to get onto the roof and maintain equipment such as heating and ventilation systems and any other services that may be located there.

Steve Hill, project manager at Lakesmere Ltd, said: “As with all Bilco units, these were delivered to the site complete and ready to install. Fixing was a speedy process requiring no special fasteners, tools or skills and the Bil-Clip flash system aided rapid installation.”

Bilco REM smoke vents are rugged ‘stand alone’ units and come fully insulated and gasketed for all weather conditions. They are covered by a five year guarantee.

In 2004, Bilco supplied six smoke vents for Phase Three of the development, an 11 storey building called Senses South. All the automatic smoke vents utilise the patented Thermolatch II positive hold/release mechanism. This unique latching device ensures reliable vent operation if a fire occurs and prevents inadvertent opening of the covers by wind, building vibrations or other factors.

Thermolatch II is equipped with a 74 degrees Celsius fusible link for automatic operation. In the event of a fire, heat breaks the fusible link, allowing powerful lifting mechanisms to open the vent covers instantaneously.

1. Access doors and vents manufacturer Bilco has completed delivery of automatic smoke vents for prestige high-rise housing at Berkeley Homes’ Chelsea Bridge Wharf development in London.

2. View of a Bilco D-50-REM smoke vent from the rooftops of the new Chelsea Bridge Wharf housing development.

3. One of 5 D-50 Bilco smoke vents installed on Phase Four of the Chelsea Bridge Wharf housing development.

Email: bilcouk@bilco.com


Addagrip Resin Bound Surfacing news 060406

Advanced Ergonomic Technologies Underfloor Air Conditioning Access Flooring news 070406

Advanced Ergonomic Technologies Underfloor Air Conditioning Access Flooring news 120406

Airedale Building HVAC Lighting Computer Simulations news 100406

Ardex UK Floor Screeds Resin Finish news 040406

Bilco UK Fire Protection Fire Detection Protection Evacuation news 070406

Bosch Security Systems Auto Dome Modular Camera System news 120406

Bosch Security Systems Auto Dome Modular Camera System news 040406

Bosch Security Systems DCN Wireless Discussion System news 040406

Carrier Air Conditioning Air Conditioning Systems Chilled Beams Splits news 060406-1

Carrier Air Conditioning Air Conditioning Systems Chilled Beams Splits news 070406

Carrier Air Conditioning Air Handling Units Fan Coils news 060406-3

Carrier Air Conditioning Chillers Air Water Cooled Heat Pumps news 060406-4

Carrier Air Conditioning Fan Coils Dry Coolers Cooling Towers news 060406-5

Carrier Air Conditioning Heat Pumps Packaged Air Conditioning news 060406-6

Carrier Air Conditioning Portable Air Conditioning Heat Pumps news 060406-2

Centraline City Air Conditioning (HVAC) Systems news 100406

CIOB Building Control Standards Facilities Management news 030406

CIOB Building Control Standards Facilities Management news 130406

Dean & Bowes Refurbishment Contractor Shop Fitting news 120406

Dortrend International Door Furniture furniture operators locks news 070406

Emergency First Response Emergency Resuscitation First Aid news 050406

Future Safety Protective Clothing Safety Signs news 040406

Honeywell Control Systems Ltd Motorised Valves Programmable Thermostats news 030406

Honeywell Control Systems Ltd Valves Pipework Systems Motorised Valves news 070406

Honeywell Control Systems Ltd Valves Pipework Systems Motorised Valves news 100406

Jackson Construction Building Services Consultants Building Services Contractors news 100406

Jackson Construction Building Services Consultants Building Services Contractors news 060406

Knauf Drywall Plasterboards Plasters Drylining Wall Linings news 100406

MR Site Services Architectural Steelwork news 040406

Polyflor Floor Flexible Covering flexible sheet news 070406

Sill Lighting UK Lighting Luminaires Accessories Lamps Tubes news 030406

S P Coil Products Doors Heaters Air Curtains Trench Heating news 110406

Toshiba Air Conditioning Systems Chilled Beams Splits news 060406-1

Toshiba Fan Coils Heat Recovery Heat Exchangers news 060406-2

Toshiba Heat Pumps Split Systems VRV VRF Condensers news 060406-3

Toshiba Heat Recovery Heat Exchangers news 060406-4

Totty Construction Contracting Building Services Specialist news 070406

TSK Group Workspace Development Office Furnishing news 130406

 

Arundel Jones Associates LLP Registered in England and Wales No. OC330189
Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL
Tel : 01622 745333 email
copyright all rights reserved

News Categories : Fire Protection Fire Detection Protection Evacuation