Colt shaft frees up valuable floor space

Colt UK has launched Colt Shaft, an active fan smoke extraction system for residential buildings, hospitals, schools/colleges, offices and hotels, that frees building designers from the constraints imposed by the need for ‘fire-fighting cores’ in these types of buildings and extracts smoke more quickly than passive natural ventilation systems.

Fire-fighting cores, which are required in buildings over 18m to an occupied top floor level, are voids containing stairs, lifts and lobbies to allow fire fighters access to any floor. These cores must be kept free from smoke and this is achieved by ventilation, either by openable windows or, if they are remote from outside walls, by a ‘BRE shaft’, which takes up a large amount of valuable floor space, or a pressurisation system which is often complex and expensive to design and install.

Colt Shaft, which is suitable for use in any fire-fighting core, requires a shaft of only 0.6m2 compared with 3m2 for the BRE shaft. This represents an 80 per cent reduction in the floor space required. It opens up the space on each floor, which allows architects to be more creative in their design, and improves the saleable or lettable space in commercial buildings for the client.

Colt Shaft also solves two common problems associated with mechanical extraction. Firstly, since the lobby is fire rated, the area of ventilation into it is usually small, so even a small amount of extract will cause a high negative pressure in the lobby, which could make doors difficult to open. Secondly, negative pressure could cause smoke to be drawn into the lobby from the fire compartment, with devastating effect.

However, Colt Shaft overcomes excessive negative pressures without compromising the integrity of the stairs and lobby by automatically reducing the ventilation rate when the lobby doors are closed. It does this via a pressure sensor linked into the control system that varies the fan speed. With all doors open, the fan runs at full speed to extract smoke discharging from the accommodation. With all doors closed, the fan runs at minimum speed to help mop up smoke leaking past the closed door. In intermediate conditions, the fan speed modulates to ensure adequate ventilation without excessive depressurisation.

Colt has conducted a comprehensive series of smoke tests, witnessed by the London Fire Brigade, which now has the confidence to accept that the Colt Shaft could perform to an equivalent standard as a standard 3m2 BRE Shaft, fitted in the same situation. The tests also showed that the system reacts quickly to pressure changes, smoke clears quickly from the lobby when the accommodation or stair doors are opened, and the lobby is kept clear of smoke once the accommodation door is closed.

With the door to accommodation closed, a typical 5m2 lobby will clear totally within 15 to 20 seconds of opening the stair door.

Email: simon.ohea@uk.coltgroup.com


Pinelog Limited Log Cabins Lodges Summerhouses news 200706

Ardex UK Ltd Screeds Renders Ceramic Adhesives Grouts news 110706

ARDEX UK Screeds Renders Ceramic Adhesives Grouts news 200706

Briggs & Forrester Contracting Building Services Specialists news 200706

British Gypsum Ltd Plaster Plasterboard and Drylining Systems news 140706

British Gypsum Plaster Plasterboard and Drylining Systems news 190706

C & B Systems Pre-plumbed Panels Cubicles Sanitary Fittings news 120706

Ced Limited cobblestone driveway paving news 200706

Chartered Institute of Building Conservation Maintenance and Refurbishment Facilities Management news 170706

Cleansair Air purification units HVAC news 200706

Colt International Car Park Ventilation Smoke Control news 140706-1

Colt International Car Park Ventilation Smoke Control news 140706-2

Colt International Car Park Ventilation Smoke Control news 140706-3

Comar Architectural Aluminium Systems Curtain Walling Metal Cladding Facades news 190706

Conder Products Sewage Treatment Septic Tanks Cess Pools news 120706

Dean & Bowes Retail New Build Leisure Building Fit Outs news 170706

Foremost Engineering Building Service Engineers news 180706

Formica Limited High Pressure Laminate formica furniture designs news 200706

Gent by Honeywell Emergency Lighting Fire Systems Detection Cabling news 170706

Greenstock Lamp Company Fluorescent Tubes Energy Saving Light Bulbs news 170706

Hunter Plastics Sanitary Concealed Systems news 130706

Jackson Construction Construction Services Specialists New Builds news 100706

Jackson Construction Construction Services Specialists news 200706

Kee Klamp Ltd disability guardrail handrail system news 130706

Marmax Products Ltd External Furniture Seating Litter Dog Waste Planters news 200706

MHS Homes Construction New Homes Rental news 120706

Mita (UK) Ltd Cable Management Floor Boxes Underfloor Services news 210706

M R Site Services Ltd Architectural Steelwork Aluminium Roof Welding news 110706

Polyflor Ltd Flexible Sheet Tiles Carpets news 200706

Polyflor Ltd Sports Surfaces Safety Flooring news 120706

PRI Limited Measurement control and protection news 120706

PRI Limited Metering Systems Services Software news 120706-2

SAS International Architectural Steelwork Ceiling Systems Ceiling Panels news 170706

SAS International Ceiling Systems Ceiling Panels Tiles news 100706

Sun Shield Window Film Films for Glass solar control safety security news 210706

Thurston Building Systems Ltd Buildings Temporary Space Prefabricated Modular news 120706-1

Thurston Building Systems Ltd Buildings Temporary Space Prefabricated Modular news 120706-2

Totty Building Services Building Services Contractor news 120706

Twyford Bathrooms professional bathroom installations news 130607-1

Twyford Bathrooms professional bathroom installations news 130706-2

Videx Security Limited Door entry systems news 210706

Vision Fire & Security CCTV security surveillance news 210706

Wernick Buildings Ltd Modular building construction installer news 180706

 

Arundel Jones Associates LLP Registered in England and Wales No. OC330189
Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL
Tel : 01622 745333 email
copyright all rights reserved

News Categories : Car Park Ventilation 
Smoke Control