Lighting the way for cricket in the West Indies
Thanks to the expertise of Abacus Lighting, the
Stanford Cricket Ground, in Antigua will be host to the
first Caribbean 20-20 competition and will also act as
an official floodlit practice venue for the Cricket
World Cup in 2007. Abacus were responsible for the
design, manufacture, installation and commissioning of
the floodlighting system.
The lighting specification was designed to 3,500 lux
horizontal and 2100 lux vertical to the wicket. The
lighting system is one of the first in the world with
floodlighting specifically designed to allow night time
'slo-mo' TV camera replays as well as the high levels of
outfield floodlighting necessary for international CTV
broadcasts. The installed floodlighting system for the
Cricket Ground is arranged as a corner mast scheme, with
each 35m mast carrying 52 Challenger 3 floodlights
fitted with 2KW HQI lamps.
Given that the location of the Islands airport is
situated within half a mile of the new Cricket Ground,
demanded that the proposed scheme would have to be
designed to ensure light pollution and the visual
obtrusion of the masts were minimised. The resulting
solution involved the specification of the Challenger 3
floodlight, ideally suited for corner mast sports
lighting installations. Compactly designed, the
floodlight incorporates an anti-glare baffle, ensuring
minimum glare to onlookers and also facilitates the use
of double-ended lamps of either 1000W or 2000W, offering
optimum optical control. The high optical performance of
the floodlights ensured the necessary lighting levels
were achieved with the lowest mast possible, as to
ensure safe operating conditions for the neighbouring
airport.
Abacus had to overcome two further challenges associated
with the specification of the high mast system. First of
all there was no crane large enough on the island to
facilitate the installation of a fixed mast. Secondly,
the chosen mast system would have to accommodate the
potential threat of hurricanes. Both challenges were
easily overcome by the specification of the Abacus base
hinged raising and lowering mast. This hinged mast
system is completely assembled at ground level and then
raised vertical upon completion via a hydraulic
counterbalance. The mast can also be lowered to ground
level in the event of a hurricane warning which allowed
for a more economical design to be put forward,.
creating significant cost savings for the client. Rather
than design a mast able to withstand hurricane wind
speeds (75 m/sec) Abacus were able to specify a mast
able to withstand wind speeds of 45m/sec. This smart
approach has also be adopted by Sangster International
Airport in Montego Bay, Jamaica where Abacus has
recently completed the floodlighting installation for
the airport apron.
Email:
jclark@abacuslighting.com
Abacus Lighting Ltd External Industrial Lighting External Landscape Lighting
news 030806-2
Abacus Lighting Ltd External Lighting External Industrial Lighting news 030806-4
Abacus Lighting Ltd External Lighting External Industrial Lighting news 030806-7
Abacus Lighting Ltd External Lighting External Landscape Lighting news 030806-3
Abacus Lighting Ltd External Lighting External Landscape Lighting news 030806-5
Abacus Lighting Ltd Landscape Lighting External Industrial Lighting news
030806-5
Abacus Lighting Ltd Lighting External External Landscape Lighting news 030806-1
Airedale International Air Conditioning Ltd Building HVAC Lighting Computer
Simulations news 280706
Airedale Leak Detection Maintenance Commissioning Consultants news 250706
Ardex UK Floor Screeds Resin Finish Screeds Renders news 260706
Ardex UK Screeds Renders Ceramic Adhesives Grouts news 260706
Arunhithe Ltd (Falco UK) External Furniture shelters cycle storage news 240706
ASTA BEAB Certification Services Electrical standards regulations news 040806
Bosch Security Systems IP Network Video Video Management Systems news 240706
British Gypsum Ltd Plaster Plasterboard and Drylining Systems news 020806
Carrier Air Conditioning Air Conditioning Systems Chilled Beams Splits news
310706
Chartered Institute of Building Facilities Management Faculty of Architecture
Surveying news 280706
Colt International Car Park Ventilation Heat Pumps news 310706
Dow Corning Sound Proofing Insulated Panels Insulation news 260706
Dow Corning Sound Proofing Insulated Panels Insulation news 310706
Dow Corning Sound Proofing Insulated Panels Insulation news 310706
Glen Dimplex Geothermal Heating Cooling Heat Pumps news 020806
Jackson Building Services Building construction refurbishment news 040806
Jackson Construction Construction Services Specialists New Builds news 280706
Johnson & Starley Ltd Condesing Boilers Hot Water Heating Boilers news 240706
Kee Klamp Ltd Balustrade system staircase handrail design news 240706
Lyons Sleeman Hoare Architectural software development news 270706
Mita (UK) Ltd Communications Cabling Systems Cable Trunking news 280706
Polyflor Ltd Flexible Sheet Tiles Carpets Flooring news 260706
Polyflor Ltd Floor Flexible Covering Flexible Sheet Tiles news 030806
Poujoulat (UK) Ltd Stainless steel chimney manufacturer news 280706
Richmond Oak Ltd Oak Conservatories Oak Orangeries news 240706
SAS International Architectural Steelwork Ceiling Systems Ceiling Panels Tiles
news 280706
SMC Charter Architects Charter Architects swimming pool leisure complex news
310706
Telschig Verfahrenstechnik GmbH Handling concrete production news 010806
Tensid uk plc Protective Coatings anti-graffiti surface finishes news 240706
Thurston Building Systems Ltd Buildings Temporary Space Prefabricated Modular
news 260706
Toshiba Air Conditioning Heat Pumps Heat Recovery Heat Exchangers news 310706
Tyco Thermal Controls Specialty Heating Floor Heating Cooling news 030806
Verint Systems Inc. Analytical Software Solutions Digital Video Security news
010806-2
Verint Systems Inc Digital Video Security Surveillance news 010806-1
Videx Security Ltd Door Entrance Systems Access Control news 010806
WatchNet EU Ltd European CCTV and Security news 310706
Wavin Plastics Drainage Underground pipes ducting news 260706
Wavin Plastics Rainwater Disposal Roof Floor Linear Drainage news 260706
Wavin Plastics Underfloor Heating Rainwater Disposal news 260706
Arundel Jones Associates LLP Registered in England and Wales No.
OC330189 Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL Tel : 01622 745333
email copyright all rights reserved
News Categories : External Lighting
External Landscape Lighting External Industrial Lighting
|