Subscribe to our weekly newsletters
Subscribe to newsletter

 

Editor's Note:  Abacus Lighting Ltd
provide:-

External LightingExternal Lighting
External Landscape LightingExternal Landscape Lighting
External Industrial LightingExternal Industrial Lighting

Request Information

Home
Include Article
Advertise
 

 

 
 

Links
Request Information
Terms of use
Contact

 

Request Facilities / Interiors product information

Request Architectural product information A-J

Request Architectural product information K-Z

Request Mechanical HVAC product information

Request Electrical product information

   
 

Lighting the way for cricket in the West Indies

Thanks to the expertise of Abacus Lighting, the Stanford Cricket Ground, in Antigua will be host to the first Caribbean 20-20 competition and will also act as an official floodlit practice venue for the Cricket World Cup in 2007. Abacus were responsible for the design, manufacture, installation and commissioning of the floodlighting system.

The lighting specification was designed to 3,500 lux horizontal and 2100 lux vertical to the wicket. The lighting system is one of the first in the world with floodlighting specifically designed to allow night time 'slo-mo' TV camera replays as well as the high levels of outfield floodlighting necessary for international CTV broadcasts. The installed floodlighting system for the Cricket Ground is arranged as a corner mast scheme, with each 35m mast carrying 52 Challenger 3 floodlights fitted with 2KW HQI lamps.

Given that the location of the Islands airport is situated within half a mile of the new Cricket Ground, demanded that the proposed scheme would have to be designed to ensure light pollution and the visual obtrusion of the masts were minimised. The resulting solution involved the specification of the Challenger 3 floodlight, ideally suited for corner mast sports lighting installations. Compactly designed, the floodlight incorporates an anti-glare baffle, ensuring minimum glare to onlookers and also facilitates the use of double-ended lamps of either 1000W or 2000W, offering optimum optical control. The high optical performance of the floodlights ensured the necessary lighting levels were achieved with the lowest mast possible, as to ensure safe operating conditions for the neighbouring airport.

Abacus had to overcome two further challenges associated with the specification of the high mast system. First of all there was no crane large enough on the island to facilitate the installation of a fixed mast. Secondly, the chosen mast system would have to accommodate the potential threat of hurricanes. Both challenges were easily overcome by the specification of the Abacus base hinged raising and lowering mast. This hinged mast system is completely assembled at ground level and then raised vertical upon completion via a hydraulic counterbalance. The mast can also be lowered to ground level in the event of a hurricane warning which allowed for a more economical design to be put forward,. creating significant cost savings for the client. Rather than design a mast able to withstand hurricane wind speeds (75 m/sec) Abacus were able to specify a mast able to withstand wind speeds of 45m/sec. This smart approach has also be adopted by Sangster International Airport in Montego Bay, Jamaica where Abacus has recently completed the floodlighting installation for the airport apron.

Email: jclark@abacuslighting.com


Abacus Lighting Ltd External Industrial Lighting External Landscape Lighting news 030806-2

Abacus Lighting Ltd External Lighting External Industrial Lighting news 030806-4

Abacus Lighting Ltd External Lighting External Industrial Lighting news 030806-7

Abacus Lighting Ltd External Lighting External Landscape Lighting news 030806-3

Abacus Lighting Ltd External Lighting External Landscape Lighting news 030806-5

Abacus Lighting Ltd Landscape Lighting External Industrial Lighting news 030806-5

Abacus Lighting Ltd Lighting External External Landscape Lighting news 030806-1

Airedale International Air Conditioning Ltd Building HVAC Lighting Computer Simulations news 280706

Airedale Leak Detection Maintenance Commissioning Consultants news 250706

Ardex UK Floor Screeds Resin Finish Screeds Renders news 260706

Ardex UK Screeds Renders Ceramic Adhesives Grouts news 260706

Arunhithe Ltd (Falco UK) External Furniture shelters cycle storage news 240706

ASTA BEAB Certification Services Electrical standards regulations news 040806

Bosch Security Systems IP Network Video Video Management Systems news 240706

British Gypsum Ltd Plaster Plasterboard and Drylining Systems news 020806

Carrier Air Conditioning Air Conditioning Systems Chilled Beams Splits news 310706

Chartered Institute of Building Facilities Management Faculty of Architecture Surveying news 280706

Colt International Car Park Ventilation Heat Pumps news 310706

Dow Corning Sound Proofing Insulated Panels Insulation news 260706

Dow Corning Sound Proofing Insulated Panels Insulation news 310706

Dow Corning Sound Proofing Insulated Panels Insulation news 310706

Glen Dimplex Geothermal Heating Cooling Heat Pumps news 020806

Jackson Building Services Building construction refurbishment news 040806

Jackson Construction Construction Services Specialists New Builds news 280706

Johnson & Starley Ltd Condesing Boilers Hot Water Heating Boilers news 240706

Kee Klamp Ltd Balustrade system staircase handrail design news 240706

Lyons Sleeman Hoare Architectural software development news 270706

Mita (UK) Ltd Communications Cabling Systems Cable Trunking news 280706

Polyflor Ltd Flexible Sheet Tiles Carpets Flooring news 260706

Polyflor Ltd Floor Flexible Covering Flexible Sheet Tiles news 030806

Poujoulat (UK) Ltd Stainless steel chimney manufacturer news 280706

Richmond Oak Ltd Oak Conservatories Oak Orangeries news 240706

SAS International Architectural Steelwork Ceiling Systems Ceiling Panels Tiles news 280706

SMC Charter Architects Charter Architects swimming pool leisure complex news 310706

Telschig Verfahrenstechnik GmbH Handling concrete production news 010806

Tensid uk plc Protective Coatings anti-graffiti surface finishes news 240706

Thurston Building Systems Ltd Buildings Temporary Space Prefabricated Modular news 260706

Toshiba Air Conditioning Heat Pumps Heat Recovery Heat Exchangers news 310706

Tyco Thermal Controls Specialty Heating Floor Heating Cooling news 030806

Verint Systems Inc. Analytical Software Solutions Digital Video Security news 010806-2

Verint Systems Inc Digital Video Security Surveillance news 010806-1

Videx Security Ltd Door Entrance Systems Access Control news 010806

WatchNet EU Ltd European CCTV and Security news 310706

Wavin Plastics Drainage Underground pipes ducting news 260706

Wavin Plastics Rainwater Disposal Roof Floor Linear Drainage news 260706

Wavin Plastics Underfloor Heating Rainwater Disposal news 260706

 

Arundel Jones Associates LLP Registered in England and Wales No. OC330189
Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL
Tel : 01622 745333 email
copyright all rights reserved

News Categories : External Lighting
External Landscape Lighting External Industrial Lighting