When one will quietly do the job of two-Dual circuit
outdoor/indoor solution for Close Control
Why put two condensing units to a dual circuit AHU,
when a single dual circuit outdoor unit can do the job
better, take up less space and make less noise? With
customers asking for such a solution, Airedale has come
up with the answer.
By linking the advanced technology of its dual circuit,
air cooled Ultima Compact Condensing Unit (UCCU) with
the dual circuit AlphaCool Close Control system,
Airedale can for the first time, offer an intelligent,
DX precision control solution that offers lower external
noise levels, increased performance, improved energy
efficiency and high ambient operation.
The UCCU offers huge reductions in external noise
levels, reducing sound pressure at 10 metres to as
little as 42 dBA* compared with 56 dBA for two standard
condensing units. To put this into context, a 3db
reduction effectively halves noise level received by the
human ear. The reductions achieved in both footprint and
noise, are even more significant when multiple outdoor
units are required.
Two heads are considered to be better than one and in
Airedale’s dual circuit/ close control solution, both
the AlphaCool and the UCCU benefit from inbuilt,
intelligent microprocessors. Whilst the indoor unit
controls the overall system, the microprocessor within
the UCCU takes care of compressor management.
Add modulating head pressure control and high
performance heat exchangers to the optional electronic
expansion valve technology of the AlphaCool and the
result is a highly efficient and versatile DX solution
with a higher end cooling capacity range of 65-90 kW.
Multi-configured options can be mixed and matched based
on three AlphaCool models (65, 80 and 90) and three
UCCU’s (50, 70 and 80). The AlphaCool is available as a
downflow or upflow unit and the UCCU in Quiet or Super
Quiet versions. Extensions to the range are likely to
follow.
The AlphaCool provides a compact footprint in precision
control environments where space is at a premium, whilst
its partner the UCCU is saving refrigerant installation
costs, as well as service area and airflow space
outside.
Email:
celia.sharp@airedale.com
Abacus Lighting Ltd External Industrial Lighting External Landscape Lighting
news 030806-2
Abacus Lighting Ltd External Lighting External Industrial Lighting news 030806-4
Abacus Lighting Ltd External Lighting External Industrial Lighting news 030806-7
Abacus Lighting Ltd External Lighting External Landscape Lighting news 030806-3
Abacus Lighting Ltd External Lighting External Landscape Lighting news 030806-5
Abacus Lighting Ltd Landscape Lighting External Industrial Lighting news
030806-5
Abacus Lighting Ltd Lighting External External Landscape Lighting news 030806-1
Airedale International Air Conditioning Ltd Building HVAC Lighting Computer
Simulations news 280706
Airedale Leak Detection Maintenance Commissioning Consultants news 250706
Ardex UK Floor Screeds Resin Finish Screeds Renders news 260706
Ardex UK Screeds Renders Ceramic Adhesives Grouts news 260706
Arunhithe Ltd (Falco UK) External Furniture shelters cycle storage news 240706
ASTA BEAB Certification Services Electrical standards regulations news 040806
Bosch Security Systems IP Network Video Video Management Systems news 240706
British Gypsum Ltd Plaster Plasterboard and Drylining Systems news 020806
Carrier Air Conditioning Air Conditioning Systems Chilled Beams Splits news
310706
Chartered Institute of Building Facilities Management Faculty of Architecture
Surveying news 280706
Colt International Car Park Ventilation Heat Pumps news 310706
Dow Corning Sound Proofing Insulated Panels Insulation news 260706
Dow Corning Sound Proofing Insulated Panels Insulation news 310706
Dow Corning Sound Proofing Insulated Panels Insulation news 310706
Glen Dimplex Geothermal Heating Cooling Heat Pumps news 020806
Jackson Building Services Building construction refurbishment news 040806
Jackson Construction Construction Services Specialists New Builds news 280706
Johnson & Starley Ltd Condesing Boilers Hot Water Heating Boilers news 240706
Kee Klamp Ltd Balustrade system staircase handrail design news 240706
Lyons Sleeman Hoare Architectural software development news 270706
Mita (UK) Ltd Communications Cabling Systems Cable Trunking news 280706
Polyflor Ltd Flexible Sheet Tiles Carpets Flooring news 260706
Polyflor Ltd Floor Flexible Covering Flexible Sheet Tiles news 030806
Poujoulat (UK) Ltd Stainless steel chimney manufacturer news 280706
Richmond Oak Ltd Oak Conservatories Oak Orangeries news 240706
SAS International Architectural Steelwork Ceiling Systems Ceiling Panels Tiles
news 280706
SMC Charter Architects Charter Architects swimming pool leisure complex news
310706
Telschig Verfahrenstechnik GmbH Handling concrete production news 010806
Tensid uk plc Protective Coatings anti-graffiti surface finishes news 240706
Thurston Building Systems Ltd Buildings Temporary Space Prefabricated Modular
news 260706
Toshiba Air Conditioning Heat Pumps Heat Recovery Heat Exchangers news 310706
Tyco Thermal Controls Specialty Heating Floor Heating Cooling news 030806
Verint Systems Inc. Analytical Software Solutions Digital Video Security news
010806-2
Verint Systems Inc Digital Video Security Surveillance news 010806-1
Videx Security Ltd Door Entrance Systems Access Control news 010806
WatchNet EU Ltd European CCTV and Security news 310706
Wavin Plastics Drainage Underground pipes ducting news 260706
Wavin Plastics Rainwater Disposal Roof Floor Linear Drainage news 260706
Wavin Plastics Underfloor Heating Rainwater Disposal news 260706
Arundel Jones Associates LLP Registered in England and Wales No.
OC330189 Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL Tel : 01622 745333
email copyright all rights reserved
News Categories : Air Conditioning portable fixed
packaged mobile
Air Handling Units Building HVAC Lighting Computer Simulations
Chillers Air Water Cooled Close Control AC Clean Rooms
Leak Detection Maintenance Commissioning Consultants
Split Systems VRV VRF Condensers
|